A flue gas denitrification equipment system treats nitrogen oxides before exhaust gas reaches the stack. It is used where coal, coke, gas, biomass, or mixed fuel creates NOx during combustion. The system adds ammonia water, urea solution, or another reducing agent into a suitable reaction area. NOx is then changed into nitrogen and water under controlled temperature. For SCR routes, catalyst modules are added to keep reaction steadier. The design is checked by gas volume, inlet NOx, dust content, sulfur condition, temperature curve, and required outlet value.
Product Parameters
|
Parameter |
Specification |
|
Process route |
SCR, SNCR, or combined SNCR-SCR |
|
Treatment object |
NOx in boiler, kiln, furnace, and process flue gas |
|
Reaction temperature |
SNCR about 850-1100 C; SCR commonly about 300-400 C |
|
Reducing agent |
Ammonia water, urea solution, or project-specified reagent |
|
Main structure |
Reactor, spray system, catalyst layer, ducting, platform, and control cabinet |
|
Control point |
Gas volume, NOx value, temperature curve, pressure drop, and ammonia escape |
Product Advantages
The spray position can be set around the real furnace temperature area, so reagent does not enter a cold section too early.
For high-dust gas, access doors and ash-cleaning space can be kept near the reactor for faster shutdown checks.
The flue gas denitrification equipment can be checked with induced draft fan data, so pressure drop is considered before production.
Use Notes

Before ordering, the gas temperature curve should be checked at normal load and low load. Dust load and sulfur content also affect nozzle cleaning, catalyst life, and pressure drop. For old boiler retrofit work, platform and duct elbow space should be measured first.
FAQ
Q: What data is needed for design?
A: Gas volume, inlet NOx, outlet requirement, temperature range, dust content, sulfur condition, boiler load change, and available space are usually checked first.
Q: Can it be used for old boilers?
A: Yes. The flue gas denitrification equipment can be made for retrofit work, but duct route and fan margin should be reviewed before drawing.
Q: Why is temperature important?
A: The reaction needs the right temperature. If the gas is too cold or too hot, reagent use may rise and NOx removal may become unstable.
Hot Tags: flue gas denitrification equipment, China flue gas denitrification equipment manufacturers, suppliers, factory, denitrification equipment, High temperature Denitrification Equipment, Low temperature Denitrification Equipment, SCR Denitrification Equipment, SNCR Denitrification Equipment, SNCR SCR Combined Denitrification Equipment